Customization: | Available |
---|---|
Material: | Elastomeric Foam Based on Synthetic Rubber |
Capability: | Rubber Air Hose |
Still deciding? Get samples of US$ 0/Box
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ArmaFlex Class 1 is a flexible insulation material that reliably protects against water vapour ingress due to its closed-cell structure.No additional water vapour barrier is required.
Property | Value /Assessment | Standard / Test Method | ||||||
Temperature Range | ||||||||
Service Temperature | Max. service temperature | + 105ºC | + 85ºC if sheet or tape is glued to the object with its whole surface. | |||||
Min. service temperature | - 50 ºC | |||||||
Thermal Conductivity | ||||||||
θm | -20 | +/- 0 | +40 | +70 | [ ºC ] | GB/T 10294, GB/T 10296 | ||
λ ≤ | 0.032 | 0.034 | 0.039 | 0.042 | [ W/(m·k) ] | |||
Water Vapour Diffusion Resistance | ||||||||
Water vapour diffusion resistance factor | μ > 10,000 | GB/T 17146 | ||||||
Water vapour permeability | ≤ 1.96 x 10-11g/(m·s·Pa) | |||||||
Fire Performance & Approvals | ||||||||
Surface spred of flame | Class 1 | BS 476 Part 7: 1997 | ||||||
Burning Behaviour of Building materials and products | Class B1 | CQC Fire Safety Performance Certification (25mm thickness specification) |
||||||
Practical fire behaviour | Does not generate flaming droplets |
Thermal insulation/protection of pipes, air ducts and vessels (incl. elbows, fittings, flanges etc.) in air conditioning, refrigeration and process equipment to prevent condensation and to save energy. Structure-borne noise reduction in service-water and waste-water installations.